CONDOR Industrial Partner

GPC130A - Condor GPC130A DC Power Source - 130 Watt Global Performance...

larger image

Request Quote
For Price
Part Number:
GPC130A
Model Number:
GPC130A
Make:
CONDOR
Lead Time:
Available
Qty In Stock:
Available

Condor GPC130A DC Power Source - 130 Watt Global Performance Switchers Simple Type: DC Power Source

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • CE marked to LVD
  • Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3
  • Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models)
  • Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601
  • Wide-range ac input 85-264 Vac

Specifications

    General
  • AC Input: 85-264 Vac, 47-63 Hz single phase.
  • Efficiency: 70% at full rated load, nominal input voltage, depending on model and load distribution.
  • Environmental: Designed for 0 to 50°C operation at full rated output power; derate output current and total output power by 2.5% per °C above 50°C. See Environmental and Packaging Specifications on next page.
  • Hold-up time: 20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
  • Input Current: Maximum input current at 120 Vac, 60 Hz with full rated output load: 3.5 A
  • Input Protection: Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.
  • Inrush Current: Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A.
  • Output Power: 100 W continuous, 165 W peak; 130 W with 26 cfm air flow. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.
  • Overload Protection: Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic. See output ratings chart for additional notes or conditions.
  • Overvoltage Protection: Main outputs: 124% ± 12% typical.
  • Temperature Coefficient: 0.03%/°C typical on all outputs.
  • Thermal Shutdown: Provided as a standard feature. Designed to protect unit from prolonged over temperature.
  • Turn-On Time: Less than 1 second at 120 Vac, 25°C (inversely proportional to input voltage and thermistor temperature).

 

Applications

  • None Available

Aliases