GPC130D - Condor GPC130D DC Power Source - 130 Watt Global Performance...
Request Quote
For Price
- Part Number:
- GPC130D
- Model Number:
- GPC130D
- Make:
- CONDOR
- Lead Time:
- Available
- Qty In Stock:
- Available
Condor GPC130D DC Power Source - 130 Watt Global Performance Switchers Simple Type: DC Power Source
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- CE marked to LVD
- Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3
- Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models)
- Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601
- Wide-range ac input 85-264 Vac
Specifications
- AC Input: 85-264 Vac, 47-63 Hz single phase.
- Efficiency: 70% at full rated load, nominal input voltage, depending on model and load distribution.
- Environmental: Designed for 0 to 50°C operation at full rated output power; derate output current and total output power by 2.5% per °C above 50°C. See Environmental and Packaging Specifications on next page.
- Hold-up time: 20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
- Input Current: Maximum input current at 120 Vac, 60 Hz with full rated output load: 3.5 A
- Input Protection: Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.
- Inrush Current: Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A.
- Output Power: 100 W continuous, 165 W peak; 130 W with 26 cfm air flow. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.
- Overload Protection: Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic. See output ratings chart for additional notes or conditions.
- Overvoltage Protection: Main outputs: 124% ± 12% typical.
- Temperature Coefficient: 0.03%/°C typical on all outputs.
- Thermal Shutdown: Provided as a standard feature. Designed to protect unit from prolonged over temperature.
- Turn-On Time: Less than 1 second at 120 Vac, 25°C (inversely proportional to input voltage and thermistor temperature).
Applications
- None Available
Aliases